<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" xml:lang="en" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">global-journal-of-research-in-engineering-a-mechanical-mechanics</journal-id>
<journal-title-group>
<journal-title>Global Journal of Research in Engineering - A : Mechanical &amp; Mechanics</journal-title>
</journal-title-group>
<issn publication-format="print">0975-5861</issn>
<issn publication-format="electronic">2249-4596</issn>
<publisher><publisher-name>Global Journals Publishing Group Incorporated</publisher-name></publisher>
<self-uri xlink:href="https://globaljournals.org/journal-seo-export/jats/73666.xml" />
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">73666</article-id>
<title-group>
<article-title>The Characteristics Of Brazed Plate Heat Exchangers With Different Chevron Angles</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Muthuraman</surname><given-names>Dr. S.</given-names></name><xref ref-type="aff" rid="aff1" />
</contrib>
</contrib-group>
<aff id="aff1">OMAN, Higher college of Technology</aff>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2011-11-25">
<day>25</day>
<month>11</month>
<year>2011</year>
</pub-date>
<volume>11</volume>
<issue>A7</issue>
<fpage>11</fpage>
<lpage>25</lpage>
<abstract><p>Introduction -Plate heat exchangers (PHEs) were introduced in the 1930s and were almost exclusively used as liquid/liquid heat exchangers in the food industries because of their ease of cleaning. Over the years, the development of the PHE has generally continued towards larger capacity, as well as higher working temperature and pressure. Recently, a gasket sealing was replaced by a brazed material, and each thermal plate was formed with a series of corrugations (herringbone or chevron). These greatly increased the pressure and the temperature capabilities.</p></abstract>
<kwd-group kwd-group-type="author-generated">
<kwd>Compact heat exchanger</kwd>
<kwd>narrow channel</kwd>
<kwd>corrugation</kwd>
<kwd>CFD</kwd>
<kwd>Nusselt number</kwd>
<kwd>pressure drop</kwd>
<kwd>condensation</kwd>
<kwd>brazed plate heat exchanger</kwd>
<kwd>R410a</kwd>
<kwd>chevron ang</kwd>
</kwd-group>
<self-uri content-type="pdf" xlink:href="https://globaljournals.org/GJRE_Volume11/2-The-Characteristics-of-Brazed-Plate-Heat-Exchangers.pdf" />
<self-uri content-type="html" xlink:href="https://globaljournals.org/scholarly-articles/the-characteristics-of-brazed-plate-heat-exchangers-with-different-chevron-angles/" />
</article-meta>
</front>
<body>
<sec>
<title>Full Text</title>
<p>Plate heat exchangers (PHEs) were introduced in the 1930s and were almost exclusively used as liquid/liquid heat exchangers in the food industries because of their ease of cleaning. Over the years, the development of the PHE has generally continued towards larger capacity, as well as higher working temperature and pressure. Recently, a gasket sealing was replaced by a brazed material, and each thermal plate was formed with a series of corrugations (herringbone or chevron). These greatly increased the pressure and the temperature capabilities.</p>
</sec>
</body>
</article>