Modeling and Mitigation on Conducted Emission for Switch Mode Power Supply

Article ID

J90M0

Modeling and Mitigation on Conducted Emission for Switch Mode Power Supply

LI Lin
LI Lin
QIU Dongmei
QIU Dongmei
YAN Wei
YAN Wei
Gao Xiang
Gao Xiang
DOI

Abstract

The switch mode power supply (SMPS) have been widely used in the electrical and electronics systems for AC-DC and DC-DC power conversion, which can generate a lot of electromagnetic interference (EMI), especially conducted emission (CE) from 9kHz to 30MHz. The traditional CE models and mechanisms have been present for three line systems, including live, neutral and ground lines, while a novel CE models and mechanisms have been proposed in the paper for two line SMPS. And the voltage division factor, isolation factor and impedance under SMPS side of artificial mains network have been studied based on high frequency parasitic parameters to analyze the CE measurement uncertainty. Moreover, three methods have been designed to reduce the CE of SMPS, such as the capacitor shunt between the source and drain electrodes of MOSFET, CM choke and crosstalk choke, and the capacitors matrix. The experiment results show that the CE of the power concentrator and colonoscopy can be suppressed well and pass EN 55022 class B, thus realize the proposed approaches good validation.

Modeling and Mitigation on Conducted Emission for Switch Mode Power Supply

The switch mode power supply (SMPS) have been widely used in the electrical and electronics systems for AC-DC and DC-DC power conversion, which can generate a lot of electromagnetic interference (EMI), especially conducted emission (CE) from 9kHz to 30MHz. The traditional CE models and mechanisms have been present for three line systems, including live, neutral and ground lines, while a novel CE models and mechanisms have been proposed in the paper for two line SMPS. And the voltage division factor, isolation factor and impedance under SMPS side of artificial mains network have been studied based on high frequency parasitic parameters to analyze the CE measurement uncertainty. Moreover, three methods have been designed to reduce the CE of SMPS, such as the capacitor shunt between the source and drain electrodes of MOSFET, CM choke and crosstalk choke, and the capacitors matrix. The experiment results show that the CE of the power concentrator and colonoscopy can be suppressed well and pass EN 55022 class B, thus realize the proposed approaches good validation.

LI Lin
LI Lin
QIU Dongmei
QIU Dongmei
YAN Wei
YAN Wei
Gao Xiang
Gao Xiang

No Figures found in article.

LI Lin. 2017. “. Global Journal of Research in Engineering – F: Electrical & Electronic GJRE-F Volume 17 (GJRE Volume 17 Issue F2): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
GJRE-F Classification: FOR Code: 290901
Keywords
Article Matrices
Total Views: 3297
Total Downloads: 1550
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Modeling and Mitigation on Conducted Emission for Switch Mode Power Supply

LI Lin
LI Lin
QIU Dongmei
QIU Dongmei
YAN Wei
YAN Wei
Gao Xiang
Gao Xiang

Research Journals