Entransy Effectiveness for Analysis of Heat Exchangers

Article ID

E53NR

Entransy Effectiveness for Analysis of Heat Exchangers

M. Khalil Anwar
M. Khalil Anwar
Mostafa H. Sharqawy
Mostafa H. Sharqawy
DOI

Abstract

The entransy effectiveness of heat exchangers relation is defined in this study. The effect of changing the number of transfer units (NTU), on entransy effectiveness for heat exchanger, is discussed. The entransy effectiveness is a measure of the irreversibility of the heat transfer process in the heat exchanger. Its behavior is same like as heat transfer effectiveness for heat exchanger. The flow pattern effect on entransy effectiveness is also discussed here. It is found that in case of counter flow type entransy effectiveness is higher than in case of parallel flow type. In addition, a detailed comparison between heat transfer effectiveness and entransy effectiveness is presented. In addition to that effect of changing heat exchanger effectiveness on entransy effectiveness is discussed here. Furthermore, the effect of changing ratio of inlet temperatures of cold fluid to inlet of hot fluid is also observed. It is found that with increase in this ratio, we have lower value of entransy effectiveness.

The entransy effectiveness of heat exchangers relation is defined in this study. The effect of changing the number of transfer units (NTU), on entransy effectiveness for heat exchanger, is discussed. The entransy effectiveness is a measure of the irreversibility of the heat transfer process in the heat exchanger. Its behavior is same like as heat transfer effectiveness for heat exchanger. The flow pattern effect on entransy effectiveness is also discussed here. It is found that in case of counter flow type entransy effectiveness is higher than in case of parallel flow type. In addition, a detailed comparison between heat transfer effectiveness and entransy effectiveness is presented. In addition to that effect of changing heat exchanger effectiveness on entransy effectiveness is discussed here. Furthermore, the effect of changing ratio of inlet temperatures of cold fluid to inlet of hot fluid is also observed. It is found that with increase in this ratio, we have lower value of entransy effectiveness.

M. Khalil Anwar
M. Khalil Anwar
Mostafa H. Sharqawy
Mostafa H. Sharqawy

No Figures found in article.

Mostafa Elsharqawy. 2017. “. Global Journal of Research in Engineering – A : Mechanical & Mechanics GJRE-A Volume 17 (GJRE Volume 17 Issue A4): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
GJRE-A Classification: FOR Code: 091399
Keywords
Article Matrices
Total Views: 3346
Total Downloads: 1584
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Entransy Effectiveness for Analysis of Heat Exchangers

M. Khalil Anwar
M. Khalil Anwar
Mostafa H. Sharqawy
Mostafa H. Sharqawy

Research Journals