Long-Term Follow-Up of Standard and Small-Diameter Implantable Cardioverter Leads

Paolo Zappulla
Paolo Zappulla
Antonio Greco
Antonio Greco
Enrico Bertagnin
Enrico Bertagnin
Daniela Dugo
Daniela Dugo
Angelo Di Grazia
Angelo Di Grazia
Valeria Calvi
Valeria Calvi
University of Catania University of Catania

Send Message

To: Author

Long-Term Follow-Up of Standard and Small-Diameter Implantable Cardioverter Leads

Article Fingerprint

ReserarchID

79399

Long-Term Follow-Up of Standard and Small-Diameter Implantable Cardioverter Leads Banner

AI TAKEAWAY

Connecting with the Eternal Ground
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scots Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sundanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
Font Type
Font Size
Font Size
Bedground

References

22 Cites in Article
  1. Arthur Moss,Wojciech Zareba,W Hall,Helmut Klein,David Wilber,David Cannom,James Daubert,Steven Higgins,Mary Brown,Mark Andrews (2002). Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection Fraction.
  2. Gust Bardy,Kerry Lee,Daniel Mark,Jeanne Poole,Douglas Packer,Robin Boineau,Michael Domanski,Charles Troutman,Jill Anderson,George Johnson,Steven Mcnulty,Nancy Clapp-Channing,Linda Davidson-Ray,Elizabeth Fraulo,Daniel Fishbein,Richard Luceri,John Ip (2005). Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure.
  3. T Kleemann,T Becker,K Doenges,M Vater,J Senges,S Schneider,W Saggau,U Weisse,K Seidl (2007). Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
  4. Daniel Kramer,Laura Hatfield,Deepa Mcgriff,Christopher Ellis,Melanie Gura,Michelle Samuel,Linda Retel,Robert Hauser (2015). Transvenous Implantable Cardioverter‐Defibrillator Lead Reliability: Implications for Postmarket Surveillance.
  5. R Rordorf,L Poggio,S Savastano,A Vicentini,B Petracci,E Chieffo,C Klersy,M Landolina (2013). Failure of implantable cardioverter-defibrillator leads: a matter of lead size?.
  6. Christopher Ellis,Jeffrey Rottman (2009). Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads.
  7. Robert Hauser,David Hayes (2009). Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure.
  8. Robert Hauser,Linda Kallinen,Adrian Almquist,Charles Gornick,William Katsiyiannis (2007). Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead.
  9. Robert Hauser,William Maisel,Paul Friedman,Linda Kallinen,Andrew Mugglin,Kapil Kumar,David Hodge,Thomas Morrison,David Hayes (2011). Longevity of Sprint Fidelis Implantable Cardioverter-Defibrillator Leads and Risk Factors for Failure.
  10. Gabor Duray,Carsten Israel,Jörn Schmitt,Stefan Hohnloser (2008). Implantable cardioverter-defibrillator lead disintegration at the level of the tricuspid valve.
  11. Vivek Kodoth,Emily Hodkinson,Rebecca Noad,Kyle Ashfield,Nicholas Cromie,David Mceneaney,Carol Wilson,Michael Roberts (2012). Fluoroscopic and Electrical Assessment of a Series of Defibrillation Leads: Prevalence of Externalized Conductors.
  12. Biotronik (2016). The Common Technical Document—A Global Format for Registration Files.
  13. Fabian Noti,Anna Lam,Nicole Klossner,Jens Seiler,Helge Servatius,Argelia Medeiros-Domingo,Vân Nam Tran,Andreas Haeberlin,Juerg Fuhrer,Hildegard Tanner,Laurent Roten (2016). Failure rate and conductor externalization in the Biotronik Linox/Sorin Vigila implantable cardioverter-defibrillator lead.
  14. Sophie Van Malderen,Tamas Szili-Torok,Sing Yap,Sanne Hoeks,Felix Zijlstra,Dominic Theuns (2016). Comparative study of the failure rates among 3 implantable defibrillator leads.
  15. Satoshi Kawada,Nobuhiro Nishii,Yoshimasa Morimoto,Akihito Miyoshi,Motomi Tachibana,Hiroyasu Sugiyama,Koji Nakagawa,Atsuyuki Watanabe,Hiroshi Morita,Hiroshi Ito (2017). Comparison of longevity and clinical outcomes of implantable cardioverter-defibrillator leads among manufacturers.
  16. Gareth Padfield,Christian Steinberg,Shahzad Karim,Stanley Tung,Matthew Bennett,John Le Maitre,Jamil Bashir (2015). Early Failure of the Biotronik Linox Implantable Cardioverter Defibrillator Lead.
  17. Abbott (2018). Product performance report.
  18. Anand Shah,David Hirsh,Jonathan Langberg (2015). User-reported abrasion-related lead failure is more common with durata compared to other implantable cardiac defibrillator leads.
  19. R Hauser,J Sengupta,E Schloss,L Stanberry,M Wananu,R Abdelhadi (2019). Internal insulation breaches in an implantable cardioverter defibrillator lead with redundant conductors.
  20. C Swerdlow,R Kass,A Khoynezhad,S Tang (2013). Inside-out insulation failure of a defibrillator lead with abrasion-resistant coating.
  21. Robert Hauser (2012). Riata externalized conductors: Cosmetic defect or manifestation of a more serious design flaw?.
  22. Jack Kron,John Herre,Ellen Renfroe,Carlos Rizo-Patron,Merritt Raitt,Blair Halperin,Michael Gold,Bruce Goldner,Mark Wathen,Bruce Wilkoff,Anna Olarte,Qing Yao (2001). Lead- and device-related complications in the Antiarrhythmics Versus Implantable Defibrillators Trial.

Funding

No external funding was declared for this work.

Conflict of Interest

The authors declare no conflict of interest.

Ethical Approval

No ethics committee approval was required for this article type.

Data Availability

Not applicable for this article.

How to Cite This Article

Paolo Zappulla. 2026. \u201cLong-Term Follow-Up of Standard and Small-Diameter Implantable Cardioverter Leads\u201d. Global Journal of Medical Research - L: Nutrition GJMR-L Volume 22 (GJMR Volume 22 Issue L1).

Download Citation

Long-Term Follow-up of Standard and Small-Diameter Implants Video for Leads.
Journal Specifications

Crossref Journal DOI 10.17406/gjmra

Print ISSN 0975-5888

e-ISSN 2249-4618

Keywords
Classification
GJMR-L Classification DDC Code: 617.4120645 LCC Code: RC684.P3
Version of record

v1.2

Issue date
July 9, 2022

Language
en
Experiance in AR

Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.

Read in 3D

Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.

Article Matrices
Total Views: 1615
Total Downloads: 56
2026 Trends
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Long-Term Follow-Up of Standard and Small-Diameter Implantable Cardioverter Leads

Paolo Zappulla
Paolo Zappulla <p>University of Catania</p>
Antonio Greco
Antonio Greco
Enrico Bertagnin
Enrico Bertagnin
Daniela Dugo
Daniela Dugo
Angelo Di Grazia
Angelo Di Grazia
Valeria Calvi
Valeria Calvi

Research Journals