Peripheral uses of a Double Lumen Balloon Microcatheter: Onyx Embolization , Anchoring and other Techniques

Article ID

406N8

Peripheral uses of a Double Lumen Balloon Microcatheter: Onyx Embolization , Anchoring and other Techniques

Eduardo Crespo Vallejo
Eduardo Crespo Vallejo
Ernesto Santos Martin
Ernesto Santos Martin
Mario Martinez-Galdamez
Mario Martinez-Galdamez
DOI

Abstract

Purpose: To evaluate the technical feasibility and safety of dual lumen balloon microcatheter Onyx embolization in peripheral interventions. Material and methods: Between January 2013 and September 2014 , seven patients underwent Onyx embolization through a double lumen balloon microcatheter. Onyx was injected as solely agent in three patients with chronic hemoptysis, two patients with life threatening organ bleeding and one with a rejected kidney graft. In one patient with a liver arterioportal fistula, a combination of coils and onyx was used through the same system. In addition to this technical implementation, we also describe three cases where an anchoring tecnhique were used in tortuous arterial anatomies in order to place micro and guide catheters in a stable position. Results: All the Onyx embolizations were completed and well tolerated. During the Onyx embolization, no reflux was noted and inmediate forward flow was identified. Technical success was 100%. The clinical outcome of the patients was satisfactory with no (peri/postprocedural) complications Conclusion: Double-lumen balloon microcatheter Onyx embolization is feasible and safe in peripheral interventions, lowering the potential complications related to reflux or Onyx migration.

Peripheral uses of a Double Lumen Balloon Microcatheter: Onyx Embolization , Anchoring and other Techniques

Purpose: To evaluate the technical feasibility and safety of dual lumen balloon microcatheter Onyx embolization in peripheral interventions. Material and methods: Between January 2013 and September 2014 , seven patients underwent Onyx embolization through a double lumen balloon microcatheter. Onyx was injected as solely agent in three patients with chronic hemoptysis, two patients with life threatening organ bleeding and one with a rejected kidney graft. In one patient with a liver arterioportal fistula, a combination of coils and onyx was used through the same system. In addition to this technical implementation, we also describe three cases where an anchoring tecnhique were used in tortuous arterial anatomies in order to place micro and guide catheters in a stable position. Results: All the Onyx embolizations were completed and well tolerated. During the Onyx embolization, no reflux was noted and inmediate forward flow was identified. Technical success was 100%. The clinical outcome of the patients was satisfactory with no (peri/postprocedural) complications Conclusion: Double-lumen balloon microcatheter Onyx embolization is feasible and safe in peripheral interventions, lowering the potential complications related to reflux or Onyx migration.

Eduardo Crespo Vallejo
Eduardo Crespo Vallejo
Ernesto Santos Martin
Ernesto Santos Martin
Mario Martinez-Galdamez
Mario Martinez-Galdamez

No Figures found in article.

Eduardo Crespo Vallejo. 2015. “. Global Journal of Medical Research – D: Radiology, Diagnostic GJMR-D Volume 15 (GJMR Volume 15 Issue D2): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjmra

Print ISSN 0975-5888

e-ISSN 2249-4618

Classification
GJMR-D Classification: NLMC Code: WU 300
Keywords
Article Matrices
Total Views: 4046
Total Downloads: 2069
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Peripheral uses of a Double Lumen Balloon Microcatheter: Onyx Embolization , Anchoring and other Techniques

Eduardo Crespo Vallejo
Eduardo Crespo Vallejo
Ernesto Santos Martin
Ernesto Santos Martin
Mario Martinez-Galdamez
Mario Martinez-Galdamez

Research Journals