Abstract

One of the major challenges with the use of solar thermal energy is the intermittent nature. As such, present day research is geared towards energy storage systems in which thermal energy is stored during the day for later use. However, in many engineering applications there is a continuous steady demand for energy. Hence, this study is focused on the optimization of a packed bed energy storage system to provide an uninterrupted continuous supply of energy in the absence of or availability of solar energy. A mathematical model was developed from consideration of the basic phenomena of heat transfer to predict the thermal behavior of a simultaneous charging, storage and discharging system during a heating cycle. Optimization of the entire storage system were carried out and it was discovered that the ratio of optimum volume to area at airflow rate of 0.0094, 0.012, 0.014, 0.017, 0.019, 0.021, 0.024, 0.026, 0.028, 0.031, 0.033, 0.035, 0.038, 0.040, 0.042 and 0.045m3/s were 0.123, 0.154, 0.185, 0.215, 0.247, 0.276, 0.308, 0.338, 0.369, 0.4, 0.43, 0.462, 0.491, 0.523, 0.554, and 0.584, respectively.

Optimization of Packed Concrete Bed Energy Storage System

One of the major challenges with the use of solar thermal energy is the intermittent nature. As such, present day research is geared towards energy storage systems in which thermal energy is stored during the day for later use. However, in many engineering applications there is a continuous steady demand for energy. Hence, this study is focused on the optimization of a packed bed energy storage system to provide an uninterrupted continuous supply of energy in the absence of or availability of solar energy. A mathematical model was developed from consideration of the basic phenomena of heat transfer to predict the thermal behavior of a simultaneous charging, storage and discharging system during a heating cycle. Optimization of the entire storage system were carried out and it was discovered that the ratio of optimum volume to area at airflow rate of 0.0094, 0.012, 0.014, 0.017, 0.019, 0.021, 0.024, 0.026, 0.028, 0.031, 0.033, 0.035, 0.038, 0.040, 0.042 and 0.045m3/s were 0.123, 0.154, 0.185, 0.215, 0.247, 0.276, 0.308, 0.338, 0.369, 0.4, 0.43, 0.462, 0.491, 0.523, 0.554, and 0.584, respectively.

Adeyanju A. A.
Adeyanju A. A. Ekiti State University
Manohar K
Manohar K

No Figures found in article.

Adeyanju A. A.. 2016. “. Global Journal of Research in Engineering – A : Mechanical & Mechanics GJRE-A Volume 15 (GJRE Volume 15 Issue A4): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
GJRE-A Classification: FOR Code: 091399
Keywords
Article Matrices
Total Views: 3974
Total Downloads: 2007
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Optimization of Packed Concrete Bed Energy Storage System

Adeyanju A. A.
Adeyanju A. A. Ekiti State University
Manohar K
Manohar K

Research Journals