Experimental Determination of Bubble Size in Solution of Surfactants of the Bubble Column

Article ID

4OZ5U

Experimental Determination of Bubble Size in Solution of Surfactants of the Bubble Column

Maedeh Asari
Maedeh Asari Shahrood University
Faramarz Hormozi
Faramarz Hormozi
DOI

Abstract

This paper focuses on the effect of surfactants on the bubble size. Bubble size in SDS/water system were investigated at various superficial gas velocities (0.13, 0.26 and 0.5 cm/s). On the other hands, Bubble diameter were determined for different values of SDS surfactant concentration. Surfactant concentration in water were 0.05, 0.02 and 0.1 vol.%. Tap water and aqueous solutions with surfactants (anionic, non-ionic and zwitterionic) are used as liquid phases. The bubbles size in this phase is determined at Cs =0.05%vol and ug=0.13cm/s. The bubbles are generated into a small-scale bubble column making of Plexiglas with height of 1.2m. High speed photography techniques are used to measure the bubble size. The experimental results were shown that bubble diameter in SDS/water system is larger than other systems. In solution of SDS, Sauter mean bubble diameter (Location A and D) decreases when superficial gas velocity increased.

Experimental Determination of Bubble Size in Solution of Surfactants of the Bubble Column

This paper focuses on the effect of surfactants on the bubble size. Bubble size in SDS/water system were investigated at various superficial gas velocities (0.13, 0.26 and 0.5 cm/s). On the other hands, Bubble diameter were determined for different values of SDS surfactant concentration. Surfactant concentration in water were 0.05, 0.02 and 0.1 vol.%. Tap water and aqueous solutions with surfactants (anionic, non-ionic and zwitterionic) are used as liquid phases. The bubbles size in this phase is determined at Cs =0.05%vol and ug=0.13cm/s. The bubbles are generated into a small-scale bubble column making of Plexiglas with height of 1.2m. High speed photography techniques are used to measure the bubble size. The experimental results were shown that bubble diameter in SDS/water system is larger than other systems. In solution of SDS, Sauter mean bubble diameter (Location A and D) decreases when superficial gas velocity increased.

Maedeh Asari
Maedeh Asari Shahrood University
Faramarz Hormozi
Faramarz Hormozi

No Figures found in article.

Maedeh Asari. 2014. “. Global Journal of Research in Engineering – C: Chemical Engineering GJRE-C Volume 14 (GJRE Volume 14 Issue C2): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
Not Found
Article Matrices
Total Views: 4482
Total Downloads: 2222
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Experimental Determination of Bubble Size in Solution of Surfactants of the Bubble Column

Maedeh Asari
Maedeh Asari Shahrood University
Faramarz Hormozi
Faramarz Hormozi

Research Journals