B. Mohammed Ishaq

Research

Colourimetric Assay of Atomoxetine Hydrochloride by Simple Aurum Coupling Reaction in Bulk and Tablet Dosage Form

Global Journal of Medical Research January 15, 2013

Simple, rapid and sensitive spectrophotometric procedure was developed for the analysis of atomoxetine hydrochloride (ATH) in pure form as well as in pharmaceutical formulations. The method was based on the reaction of ATH with gold (III) chloride in the pH range 3.5-4.5 forming violet colored complex solution, showing absorption maxima at 550 nm. The linear plot indicates that BeerÒ€ℒs law is obeyed in the range of 5 Γ’β‚¬β€œ 80 μg/ml of atomoxetine hydrochloride. The molar absorptivity and SandellÒ€ℒs sensitivity are 3.77 x 103M and 0.0774 μg cm-2 respectively. The standard deviation of the method for ten determinations ATH is 9.9827 x 103. The correlation coefficient (r2) of the experimental data of the calibration plot is 0.9997. The effective range of concentration for accurate determination of ATH as ascertained from RingbomÒ€ℒs plot and it is 10 Γ’β‚¬β€œ 80 μg/ml.