A Correlation for the Pool Boiling Enhancement Factor from Low Finned Tubes

Article ID

2GZI2

A Correlation for the Pool Boiling Enhancement Factor from Low Finned Tubes

Ali HussainTarrad
Ali HussainTarrad
Damiaa Saad Khudor
Damiaa Saad Khudor
DOI

Abstract

The present work is devoted to formulate the enhancement factor of single enhanced, integrally machined finned tube boiling pure liquids in terms of active measures related to the boiling process. A new suggested correlation for the estimation of the nucleate pool boiling heat transfer coefficient was developed. The effects of the convective term due to the phase density differences and operating pressure on the boiling process were considered to stand independently. Eleven liquids, R-11, R-12, R-22, R-113, R-114,R123, R124, 134a, n-pentane, ethanol, water, boiling on the low finned tube, at different pressure for a heat flux in the range between (10) and (50) kW/m2 were considered. The total mean absolute error of the enhancement factors was (13.3%) for the whole range of data points. It was improved to be (10.8 %) for more than (95 %) of the data points. The correlation revealed its sensitive dependency for the enhancement factor on the parameters selected for its formulation. Most of the predicted enhancement factor values fell within (± 25) %deviation from the experimental data.

A Correlation for the Pool Boiling Enhancement Factor from Low Finned Tubes

The present work is devoted to formulate the enhancement factor of single enhanced, integrally machined finned tube boiling pure liquids in terms of active measures related to the boiling process. A new suggested correlation for the estimation of the nucleate pool boiling heat transfer coefficient was developed. The effects of the convective term due to the phase density differences and operating pressure on the boiling process were considered to stand independently. Eleven liquids, R-11, R-12, R-22, R-113, R-114,R123, R124, 134a, n-pentane, ethanol, water, boiling on the low finned tube, at different pressure for a heat flux in the range between (10) and (50) kW/m2 were considered. The total mean absolute error of the enhancement factors was (13.3%) for the whole range of data points. It was improved to be (10.8 %) for more than (95 %) of the data points. The correlation revealed its sensitive dependency for the enhancement factor on the parameters selected for its formulation. Most of the predicted enhancement factor values fell within (± 25) %deviation from the experimental data.

Ali HussainTarrad
Ali HussainTarrad
Damiaa Saad Khudor
Damiaa Saad Khudor

No Figures found in article.

Ali Hussain Tarrad. 2014. “. Global Journal of Research in Engineering – A : Mechanical & Mechanics GJRE-A Volume 14 (GJRE Volume 14 Issue A5): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
Not Found
Article Matrices
Total Views: 4640
Total Downloads: 2269
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

A Correlation for the Pool Boiling Enhancement Factor from Low Finned Tubes

Ali HussainTarrad
Ali HussainTarrad
Damiaa Saad Khudor
Damiaa Saad Khudor

Research Journals