Assessment of Water Quality and Power Consumption in Small Size Reverse Osmosis Water Treatment Units

Article ID

5JELT

Assessment of Water Quality and Power Consumption in Small Size Reverse Osmosis Water Treatment Units

Khan Md. Rabbani Rasha
Khan Md. Rabbani Rasha
Quazi Hamidul Bari
Quazi Hamidul Bari
DOI

Abstract

This study is based on comparative study of different water quality parameters such as pH, turbidity, electrical conductivity (EC), chloride, total solids (TS), total dissolved solids (TDS), hardness, color, dissolved oxygen (DO), total coliform (TC), fecal coliform (FC) and total chlorine for both raw water and reverse osmosis treated water from four different locations. Most of the water quality parameters tested for raw water was above the permissible limit according to World Health Organization (WHO) with the exception of turbidity and total chlorine. All the contaminants had a removal efficiency more than 90% except hardness (57.71%) and turbidity (22.50%) for treated water. The water quality index (WQI) shows that raw water from all four locations belongs to the poor water category and treated water belongs to the excellent water category. The highest monthly cost for the electricity being monitored is 38.1 Tk. ($0.45). The maximum water production was noticed for the month of october at 1021 liters and the per cubic meter water production cost for RO water treatment system was at 27 Tk. ($0.32).

Assessment of Water Quality and Power Consumption in Small Size Reverse Osmosis Water Treatment Units

This study is based on comparative study of different water quality parameters such as pH, turbidity, electrical conductivity (EC), chloride, total solids (TS), total dissolved solids (TDS), hardness, color, dissolved oxygen (DO), total coliform (TC), fecal coliform (FC) and total chlorine for both raw water and reverse osmosis treated water from four different locations. Most of the water quality parameters tested for raw water was above the permissible limit according to World Health Organization (WHO) with the exception of turbidity and total chlorine. All the contaminants had a removal efficiency more than 90% except hardness (57.71%) and turbidity (22.50%) for treated water. The water quality index (WQI) shows that raw water from all four locations belongs to the poor water category and treated water belongs to the excellent water category. The highest monthly cost for the electricity being monitored is 38.1 Tk. ($0.45). The maximum water production was noticed for the month of october at 1021 liters and the per cubic meter water production cost for RO water treatment system was at 27 Tk. ($0.32).

Khan Md. Rabbani Rasha
Khan Md. Rabbani Rasha
Quazi Hamidul Bari
Quazi Hamidul Bari

No Figures found in article.

khan_md_rabbani_rasha. 2021. “. Global Journal of Research in Engineering – C: Chemical Engineering GJRE-C Volume 21 (GJRE Volume 21 Issue C1): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Classification
GJRE-C Classification: FOR Code: 090499
Keywords
Article Matrices
Total Views: 2090
Total Downloads: 952
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Assessment of Water Quality and Power Consumption in Small Size Reverse Osmosis Water Treatment Units

Khan Md. Rabbani Rasha
Khan Md. Rabbani Rasha
Quazi Hamidul Bari
Quazi Hamidul Bari

Research Journals