Loading menu…

Comparison of Isolated Pad Footing and Beam-Slab Isolated Footing based on Varying the Footing size and Grade of Steel

§ Manipal Institute of Technology

Send Message

To: Author

Comparison of Isolated Pad Footing and Beam-Slab Isolated Footing based on Varying the Footing size and Grade of Steel

Article Fingerprint

ReserarchID

41197

Comparison of Isolated Pad Footing and Beam-Slab Isolated Footing based on Varying the Footing size and Grade of Steel Banner

Key Research Insights

Synthesized scholarly intelligence & interactive research assistant
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scots Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sundanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
Reading Preferences
Font Size
Line Spacing
Background
This converted HTML version may contain rendering inconsistencies. Please refer to the PDF for the authoritative version, or click here to provide feedback.

Abstract

This paper presents a comparison of isolated pad footing with the Beam-Slab Isolated footing. In this paper beams have been introduced in the isolated pad footing to accommodate the tension in the footing. This in return reduces the overall depth of the footing. The design has been carried out to satisfy the Flexural and shear values for the foundation as per IS 456:2000. The diameter of the bar is decided such as to ensure that the area of steel provided is closest to the steel required as per the Limit State Design. Graphs are prepared to analyze the steel and concrete required for varying sizes of the footing (starting from 1m upto 6 m with a 0.5m increment) and comparing the values for 415 and Fe 500 steel values

References

3 Cites in Article
  1. 1. M. Al-Ansari (2013). Structural Cost of Optimized Reinforced Concrete Isolated Footing. International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering, 290, 290-297.
  2. 2. (2000). IS 456:2000 Plain and Reinforced Concrete- Code of Practice (Fourth Revision), tenth reprint, April 2007. Plain and Reinforced Concrete- Code of Practice (Fourth Revision
  3. 3. S. Sharma,M. Vanza,D. Mehta (2014). Comparison of Raft foundation and Beam & Slab Raft Foundation for High Rise Building. International Journal of Engineering Development and Research, 571, 571-575.

Funding

No external funding was declared for this work.

Conflict of Interest

The authors declare no conflict of interest.

Ethical Approval

No ethics committee approval was required for this article type.

Data Availability

Not applicable for this article.

How to Cite This Article

Ishani Singal. 2017. "Comparison of Isolated Pad Footing and Beam-Slab Isolated Footing based on Varying the Footing size and Grade of Steel". Global Journal of Research in Engineering - E: Civil & Structural GJRE-E Volume 16 (GJRE Volume 16 Issue 28 (E5)).

More Citation Formats

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Keywords
Classification
GJRE-E Classification FOR Code: 090502
Version of record
v1.2

Issue date
December 5, 2016

Language
English
Order Article Reprint
Experience in AR

Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.

Read in 3D

Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.

Article Matrices
Total Views: 1.8K
Total Downloads: 146
All Trends

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Comparison of Isolated Pad Footing and Beam-Slab Isolated Footing based on Varying the Footing size and Grade of Steel

Ishani Singal
Ishani Singal Manipal Institute of Technology