Design, Analysis and Performance Study of a Hybrid PV-Diesel- Wind System for a Village Gopal Nagar in Comilla

Design, Analysis and Performance Study of a Hybrid PV-Diesel- Wind System for a Village Gopal Nagar in Comilla

Article Fingerprint

ReserarchID

2KZ2J

Design, Analysis and Performance Study of a Hybrid PV-Diesel- Wind System for a Village Gopal Nagar in Comilla Banner

Key Research Insights

Synthesized scholarly intelligence & interactive research assistant
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scots Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sundanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
Reading Preferences
Font Size
Line Spacing
Background
This converted HTML version may contain rendering inconsistencies. Please refer to the PDF for the authoritative version, or click here to provide feedback.

Abstract

In this report, a hybrid power system has been designed considering photovoltaic, wind turbine generator and diesel generator. HOMER software has been used for analyzing the performance of the system. Different performance analysis like feasibility, sensitivity, cost, and sustainability has been done. Environmental and economic analysis is used to discuss the sustainability of a hybrid power system. Primary ac loads for 24 hours, solar resource and wind resource inputs for a year are used. Analysis reveals that the hybrid system with photovoltaic, diesel generator, wind turbine give better performance in terms of cost and sensitivity.

References

8 Cites in Article
  1. 1. J Duffe,W Beckman (1980). Solar Engineering of Thermal Processes. Solar Engineering of Thermal Processes
  2. 2. Design (2007). Analysis and Performance Study of a Hybrid PV-Diesel-Wind System for a Village Gopal Nagar in Comilla 2. Final Report of Solar and Wind Energy Resource Assessment (SWERA) -Bangladesh Project
  3. 3. D Saheb-Koussa,M Haddadi,M Belhamel (2009). Economic and technical study of a hybrid system (wind–photovoltaic–diesel) for rural electrification in Algeria. Applied Energy, 86(7-8), 1024-1030.
  4. 4. S Shaahid,I El-Amin (2009). Techno-economic evaluation of off-grid hybrid photovoltaic-dieselbattery power systems for rural electrification in Saudi Arabia-A way forward for sustainable development. Renewable and Sustainable Energy Reviews, 13(3), 625-633.
  5. 5. S Shaahid,I El-Amin,S Rehman,A Al-Shehri,J Bakashwain,F Ahmad (2004). Potential of Autonomous/Off-Grid Hybrid Wind-Diesel Power System for Electrification of a Remote Settlement in Saudi Arabia. Wind Engineering, 28(5), 621-627.
  6. 6. M Elhadidy,S Shaahid (1999). Feasibility of hybrid (wind + solar) power systems for Dhahran, Saudi Arabia. Renewable Energy, 16(1-4), 970-976.
  7. 7. S Shaahid,M Elhadidy (1994). Wind and solar energy at Dhahran, Saudi Arabia. Renewable Energy, 4(4), 441-445.
  8. 8. Joel Bluestein,Elizabeth Salerno,Lori Bird,Laura Vimmerstedt (2011). Incorporating Wind Generation in Cap and Trade Programs. Incorporating Wind Generation in Cap and Trade Programs

Funding

No external funding was declared for this work.

Conflict of Interest

The authors declare no conflict of interest.

Ethical Approval

No ethics committee approval was required for this article type.

Data Availability

Not applicable for this article.

How to Cite This Article

Mohammad Mozammel Hoque, Ifte Khairul Alam Mithu, Rajib Ahmed, dipu6174. 2012. "Design, Analysis and Performance Study of a Hybrid PV-Diesel- Wind System for a Village Gopal Nagar in Comilla". Global Journal of Science Frontier Research - A: Physics & Space Science GJSFR-A Volume 12 (GJSFR Volume 12 Issue A5).

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/GJSFR

Print ISSN 0975-5896

e-ISSN 2249-4626

Keywords
Classification
GJSFR-A Classification FOR Code: 850599
Version of record

v1.2

Issue date
August 8, 2012

Language
English
Order Article Reprint
Experiance in AR

Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.

Read in 3D

Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.

Article Matrices
Total Views: 1.7K
Total Downloads: 75
All Trends

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Design, Analysis and Performance Study of a Hybrid PV-Diesel- Wind System for a Village Gopal Nagar in Comilla

Mohammad Hoque
Mohammad Hoque University of Dhaka
Ifte Mithu
Ifte Mithu
Rajib Ahmed
Rajib Ahmed