Objectives: To evaluate the effect of irradiation time on the Vickers hardness value of two bulk-fill resin-based composites. Methods: Vickers hardness (HV) of nano-hybrid resin-based composites (RBCs) containing a novel monomer composition based on tricyclodecane– urethane structure (TCD-urethane) [Venus Diamond Bulk Fill, Hearus Kulzer, Germany] compared to conventionally formulated nano-hybrid RBCs [TetricEvo- Ceram Bulk Fill, IvoclarVivadent] for 20 and 40 second using (Elipar S10, 3M ESPE, St. Paul, MN, USA). Results: The highest hardness value was shown in Bulk Fill 60 sec (HV= 65.15 2.22), while the lowest was observed in Bulk Fill TetricEvo Ceram 40 sec (HV= 61.03 1.63). There is no significant increase in Hardness value during irradiation time for both Bulk Fill Venus Diamond (p=0.456), and Bulk Fill TetricEvo Ceram (p=0.288). Conclusion: The mode of polymerization and the light-curing time did not affect on the hardness value of the nanofilled composite resin.

Effect of Curing Protocol on the Physical Properties of Bulk-Fill Resin based Composites using Novel Monomer

Objectives: To evaluate the effect of irradiation time on the Vickers hardness value of two bulk-fill resin-based composites. Methods: Vickers hardness (HV) of nano-hybrid resin-based composites (RBCs) containing a novel monomer composition based on tricyclodecane– urethane structure (TCD-urethane) [Venus Diamond Bulk Fill, Hearus Kulzer, Germany] compared to conventionally formulated nano-hybrid RBCs [TetricEvo- Ceram Bulk Fill, IvoclarVivadent] for 20 and 40 second using (Elipar S10, 3M ESPE, St. Paul, MN, USA). Results: The highest hardness value was shown in Bulk Fill 60 sec (HV= 65.15 2.22), while the lowest was observed in Bulk Fill TetricEvo Ceram 40 sec (HV= 61.03 1.63). There is no significant increase in Hardness value during irradiation time for both Bulk Fill Venus Diamond (p=0.456), and Bulk Fill TetricEvo Ceram (p=0.288). Conclusion: The mode of polymerization and the light-curing time did not affect on the hardness value of the nanofilled composite resin.

Dr. Hicham Nuaimi
Dr. Hicham Nuaimi

No Figures found in article.

Dr. Hicham Nuaimi. 2014. “. Global Journal of Medical Research – J: Dentistry & Otolaryngology GJMR-J Volume 14 (GJMR Volume 14 Issue J6): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjmra

Print ISSN 0975-5888

e-ISSN 2249-4618

Classification
Not Found
Article Matrices
Total Views: 4387
Total Downloads: 2278
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Effect of Curing Protocol on the Physical Properties of Bulk-Fill Resin based Composites using Novel Monomer

Dr. Hicham Nuaimi
Dr. Hicham Nuaimi

Research Journals