Article Fingerprint
ReserarchID
VVZ04
This study of the Electrical Load Evaluation in Igwuruta, Port Harcourt for improved distribution. Electrical load analysis identities potential problems in the distribution network such as energy usage, harmonic inference, unexpected spikes that a visual inspection alone may not identify. The 33KV Old Airport feeders that supply electricity to Igwuruta, Port Harcourt was critically examined in this study. This study used Electrical Transient Analyzer Programme (ETAP) and from the simulation, the existing distribution network had overloading of transformers and low voltage profile. To solve the problems, optimal capacitor bank of 48000KVR were introduced to the entire system network to improve voltage performance and voltage upgrade on the distribution network. The simulation of the improved distribution network shows that the voltage profile has improved with the statutory limit between 95% -105% and by the penetration of the capacitor bank in the network, the voltage was improved by 18.4% bus 2, bus 3: 18.4% and bus 27: 5.96% and all the transformer were within the normal operating condition.
Okachi Cheta Emmanuel. 2020. \u201cElectrical Load Evaluation in Igwuruta, Port Harcourt for Improved Distribution\u201d. Global Journal of Research in Engineering - F: Electrical & Electronic GJRE-F Volume 20 (GJRE Volume 20 Issue F1): .
Crossref Journal DOI 10.17406/gjre
Print ISSN 0975-5861
e-ISSN 2249-4596
Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.
Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.
Total Score: 108
Country: Nigeria
Subject: Global Journal of Research in Engineering - F: Electrical & Electronic
Authors: Okachi Cheta Emmanuel, Engr. Dr. S. L. Braide Ph.D, Prof. D C.Idoniboyeobu (PhD/Dr. count: 1)
View Count (all-time): 192
Total Views (Real + Logic): 2559
Total Downloads (simulated): 1132
Publish Date: 2020 04, Mon
Monthly Totals (Real + Logic):
This paper attempted to assess the attitudes of students in
Advances in technology have created the potential for a new
Inclusion has become a priority on the global educational agenda,
This study of the Electrical Load Evaluation in Igwuruta, Port Harcourt for improved distribution. Electrical load analysis identities potential problems in the distribution network such as energy usage, harmonic inference, unexpected spikes that a visual inspection alone may not identify. The 33KV Old Airport feeders that supply electricity to Igwuruta, Port Harcourt was critically examined in this study. This study used Electrical Transient Analyzer Programme (ETAP) and from the simulation, the existing distribution network had overloading of transformers and low voltage profile. To solve the problems, optimal capacitor bank of 48000KVR were introduced to the entire system network to improve voltage performance and voltage upgrade on the distribution network. The simulation of the improved distribution network shows that the voltage profile has improved with the statutory limit between 95% -105% and by the penetration of the capacitor bank in the network, the voltage was improved by 18.4% bus 2, bus 3: 18.4% and bus 27: 5.96% and all the transformer were within the normal operating condition.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.