Reduction of Radiation Dose and Relative Risk of Cancer Induction to Neonates Receiving Anterior-Posterior Chest X-Rays

Article ID

SFR7AJ1Q

Reduction of Radiation Dose and Relative Risk of Cancer Induction to Neonates Receiving Anterior-Posterior Chest X-Rays

Annemari Groenewald
Annemari Groenewald University of Stellenbosch and Tygerberg Academic Hospital
Willem A Groenewald
Willem A Groenewald
DOI

Abstract

Background: Chest anterior-posterior (AP) x-ray imaging is used to diagnose and follow up conditions of the heart and lungs in neonates. As neonates are more sensitive to radiation and have longer life expectancies ionizing radiation may increase the risk of cancer induction in this patient population. By using a computed radiography (CR) system acceptable images, requiring lower doses of radiation, may be produced digitally. However, radiation dose reduction is often associated with reduced image quality. Objectives: To derive exposure protocols that decrease the entrance surface dose (ESD) and relative cancer induction risk, while maintaining acceptable visual image quality. Methods and materials: A phantom was designed and used to experimentally optimise x-ray imaging protocols by varying exposure technique factors, such astube voltage and current, exposure time and filtration. Images were ranked according to measured ESDs, visual image quality and relative cancer induction risks. Results: Comparison of derived protocols to a standard neonatal chest exposure protocol revealed that the ESD was reduced approximately by 63% while image quality was improved by about 27%. Relative cancer induction risk analysis showed that, despite reduced ESDs, the risk could be greater than the standard exposure risk. Conclusion: Six exposure options that answer the aim were derived. The most optimal combination of decrease in the ESD and relative cancer induction risk with maintenance of visual image quality is a processed image at 57 kV, 2 mAs, 100 cm focus-to-film distance (FFD), fine focus, tight collimation and 0.1 mm Cu (copper) and 1 mm Al (aluminium) additional filtration.

Reduction of Radiation Dose and Relative Risk of Cancer Induction to Neonates Receiving Anterior-Posterior Chest X-Rays

Background: Chest anterior-posterior (AP) x-ray imaging is used to diagnose and follow up conditions of the heart and lungs in neonates. As neonates are more sensitive to radiation and have longer life expectancies ionizing radiation may increase the risk of cancer induction in this patient population. By using a computed radiography (CR) system acceptable images, requiring lower doses of radiation, may be produced digitally. However, radiation dose reduction is often associated with reduced image quality. Objectives: To derive exposure protocols that decrease the entrance surface dose (ESD) and relative cancer induction risk, while maintaining acceptable visual image quality. Methods and materials: A phantom was designed and used to experimentally optimise x-ray imaging protocols by varying exposure technique factors, such astube voltage and current, exposure time and filtration. Images were ranked according to measured ESDs, visual image quality and relative cancer induction risks. Results: Comparison of derived protocols to a standard neonatal chest exposure protocol revealed that the ESD was reduced approximately by 63% while image quality was improved by about 27%. Relative cancer induction risk analysis showed that, despite reduced ESDs, the risk could be greater than the standard exposure risk. Conclusion: Six exposure options that answer the aim were derived. The most optimal combination of decrease in the ESD and relative cancer induction risk with maintenance of visual image quality is a processed image at 57 kV, 2 mAs, 100 cm focus-to-film distance (FFD), fine focus, tight collimation and 0.1 mm Cu (copper) and 1 mm Al (aluminium) additional filtration.

Annemari Groenewald
Annemari Groenewald University of Stellenbosch and Tygerberg Academic Hospital
Willem A Groenewald
Willem A Groenewald

No Figures found in article.

Annemari Groenewald. 2014. “. Global Journal of Science Frontier Research – A: Physics & Space Science GJSFR-A Volume 14 (GJSFR Volume 14 Issue A3): .

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/GJSFR

Print ISSN 0975-5896

e-ISSN 2249-4626

Issue Cover
GJSFR Volume 14 Issue A3
Pg. 33- 39
Classification
Not Found
Keywords
Article Matrices
Total Views: 4349
Total Downloads: 2348
2026 Trends
Research Identity (RIN)
Related Research
Our website is actively being updated, and changes may occur frequently. Please clear your browser cache if needed. For feedback or error reporting, please email [email protected]

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

Quote and Order Details

Contact Person

Invoice Address

Notes or Comments

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Reduction of Radiation Dose and Relative Risk of Cancer Induction to Neonates Receiving Anterior-Posterior Chest X-Rays

Annemari Groenewald
Annemari Groenewald University of Stellenbosch and Tygerberg Academic Hospital
Willem A Groenewald
Willem A Groenewald

Research Journals