Article Fingerprint
ReserarchID
L78S4
Non-union after closed femoral interlock nailing is an uncommon complication and occurs when a patient starts early weight-bearing, due to faulty surgical technique or after retrauma. Removal of broken with broken locking bolt is a difficult and challenging procedure. The present case report deals with a case of the broken intramedullary nail with a broken distal locking bolt. A 30 years male patient was inserted interlocking nail for fracture shaft femur five years back. He presented with pain with instability and inability in weight-bearing after re-trauma. An X-ray revealed a broken nail with a broken distal locking bolt. The far fragment of the broken bolt was engaging bone and nail both and was the main obstacle. His nail with the broken bolt removed and re-nailing did in a single sitting. Steinmann pin (St.pin) was inserted through the distal piece of the nail to push the trapped small screw piece.
Prof. Sanjeev Sharma. 2020. \u201cRemoval of Broken Intramedullary Femoral Nail with Broken Distal Locking Bolt – A Case Report\u201d. Global Journal of Medical Research - H: Orthopedic & Musculoskeletal System GJMR-H Volume 20 (GJMR Volume 20 Issue H3): .
Crossref Journal DOI 10.17406/gjmra
Print ISSN 0975-5888
e-ISSN 2249-4618
Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.
Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.
Total Score: 119
Country: India
Subject: Global Journal of Medical Research - H: Orthopedic & Musculoskeletal System
Authors: Prof. Sanjeev Sharma, Dr. Suman Sharma, Dr. Manorma Singh, Dr. Rahul Sharma (PhD/Dr. count: 3)
View Count (all-time): 195
Total Views (Real + Logic): 2312
Total Downloads (simulated): 1013
Publish Date: 2020 07, Tue
Monthly Totals (Real + Logic):
This paper attempted to assess the attitudes of students in
Advances in technology have created the potential for a new
Inclusion has become a priority on the global educational agenda,
Non-union after closed femoral interlock nailing is an uncommon complication and occurs when a patient starts early weight-bearing, due to faulty surgical technique or after retrauma. Removal of broken with broken locking bolt is a difficult and challenging procedure. The present case report deals with a case of the broken intramedullary nail with a broken distal locking bolt. A 30 years male patient was inserted interlocking nail for fracture shaft femur five years back. He presented with pain with instability and inability in weight-bearing after re-trauma. An X-ray revealed a broken nail with a broken distal locking bolt. The far fragment of the broken bolt was engaging bone and nail both and was the main obstacle. His nail with the broken bolt removed and re-nailing did in a single sitting. Steinmann pin (St.pin) was inserted through the distal piece of the nail to push the trapped small screw piece.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.