Simulation of Load Variation Impacts on a Delta Modulated Inverter

§ Rajshahi University of Engineering & Technology (RUE...

Send Message

To: Author

Simulation of Load Variation Impacts on a  Delta Modulated Inverter

Article Fingerprint

ReserarchID

RE6S7X3

Simulation of Load Variation Impacts on a  Delta Modulated Inverter Banner

AI TAKEAWAY

Connecting with the Eternal Ground
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scots Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sundanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
Font Type
Font Size
Font Size
Bedground

Abstract

A new concept of identifying the most preferable load to be connected in a single phase full bridge inverter undergoing delta modulation has been provided in this paper. The best load is selected depending on the minimized Total Harmonic Distortion (THD) that depicts the presence of little amount of harmonics at the output response of the inverter as it is undisputedly the case that harmonics cause some perilous effects including unbalance and excessive neutral currents, interference in nearby communication networks and disturbance to other consumers, torque pulsations in electric motors and so forth. This paper reveals that a full bridge inverter operates more precisely with RC load having only 0.4084% THD as compared to RLC load and RL load. As a consequence, based on this, RC load has been considered as the most likely used load.

References

15 Cites in Article
  1. B Bedford,R Hoft (1964). JOHN WILEY & SONS, INC..
  2. Iran Azim,Habibur,Rahman (2013). Analysis & Simulation of Total Harmonic Distortion in Hysteresis Inverter.
  3. Wang Zhao-An,huangjun (2000). Power Electronic Technology.
  4. Imran Azim,Habibur Rahman (2013). Harmonics Reduction of a Single Phase Half Bridge Inverter.
  5. Charan Langton (2011). Fourier Transform made Easy Part1.
  6. H Muhammad,Rashid Power Electronics Circuits, Devices, and Applications.
  7. Devis Fewson (1998). Introduction to Power Electronics.
  8. Ahmad Albanna (2011). Modeling & Simulation of Hysteresis Current Controlled Inverters Using MATLAB.
  9. Yun Liang,Wang,Qi Liang Guo (2011). Hysteresis Current Control technique Based on Space Vector Modulation for Active Power Filter.
  10. B Vasantha Reddy,B Babu (2009). Hysteresis Controller and Delta Modulator-Two Viable Schemes for Current Controlled Voltage Source Inverter.
  11. M Kazmierkowski,L Malesani (1998). Current control techniques for three-phase voltage-source PWM converters: a survey.
  12. Bhim Singh,Kamal Al-Haddad,Ambrish Chandra (1999). A Review of Active Filters for Power Quality Improvement.
  13. D Steeper,R Stratford (1976). Reactive Compensation and Harmonic Suppression for Industrial Power Systems using Thyristor Converter.
  14. A Onah (2012). Harmonics: Generation And Suppression In AC System Networks.
  15. Valery Vodovoboz (2010). Introduction to Power Electronics.

Funding

No external funding was declared for this work.

Conflict of Interest

The authors declare no conflict of interest.

Ethical Approval

No ethics committee approval was required for this article type.

Data Availability

Not applicable for this article.

How to Cite This Article

Habibur Rahman, Imran Azim. 1970. "Simulation of Load Variation Impacts on a Delta Modulated Inverter". Global Journal of Research in Engineering, Global Journal of Research in Engineering - F: Electrical & Electronic GJRE-F Volume 13 (GJRE Volume 13 Issue F6).

Download Citation

Journal Specifications

Crossref Journal DOI 10.17406/gjre

Print ISSN 0975-5861

e-ISSN 2249-4596

Keywords
Classification
GJRE-F Classification FOR Code: 090699
Version of record

v1.2

Language
English
Experiance in AR

Explore published articles in an immersive Augmented Reality environment. Our platform converts research papers into interactive 3D books, allowing readers to view and interact with content using AR and VR compatible devices.

Read in 3D

Your published article is automatically converted into a realistic 3D book. Flip through pages and read research papers in a more engaging and interactive format.

Article Matrices
Total Views: 3.9K
Total Downloads: 253
All Trends

Request Access

Please fill out the form below to request access to this research paper. Your request will be reviewed by the editorial or author team.
X

This is the heading

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

High-quality academic research articles on global topics and journals.

Simulation of Load Variation Impacts on a Delta Modulated Inverter

Habibur Rahman
Habibur Rahman Rajshahi University of Engineering & Technology (RUET), Rajshahi-6204.
Imran Azim
Imran Azim